Series 1/16 DIN Universal Process Controller
|
|
The Athena Legacy 16 is a 1/16 DIN panel mounted, auto-tuning controller that can be used for precise control of a single loop with two independent outputs. The controller accepts thermocouple, RTD, voltage, or current input. RS-232 or RS-485 communications are available, and two digital LED displays provide visual indication of various controller functions.
• User-Selectable Ramp to Setpoint
• Bumpless Auto/Manual Transfer
• NEMA 4X (IP65) Dust and Splash-Proof Front Panel
• On/Off through Full PID Operation (P,PI,PD,PID)
• Auto-Tuning, Heat or Cool
• Adjustable Hysteresis & Heat/Cool Spread
• Field-Configurable Process, Deviation, or Latching or Non-Latching Alarms
• Remote Setpoint Select Option
• Dual Output/Dual Alarm Capabilities
• Optional Process Variable Retransmission
• DIN Rail Option
• cUL and CE Approvals
Downloads
Datasheet
Manual
Configuration Record Form
|
|
|
Series 25
|
|
The Athena Legacy 25 is a 1/4 DIN panel mounted, auto-tuning controller that can be used for precise control of a single loop with two independent outputs. The controller accepts thermocouple, RTD, voltage, or current input. RS-232 or RS-485 communications are available, and two digital LED displays provide visual indication of various controller functions.
• User-Selectable Ramp to Setpoint
• Bumpless Auto/Manual Transfer
• NEMA 4X (IP65) Dust and Splash-Proof Front Panel
• On/Off through Full PID Operation (P,PI,PD,PID)
• Auto-Tuning, Heat or Cool
• Adjustable Hysteresis & Heat/Cool Spread
• Field-Configurable Process, Deviation, or Latching Alarms
• Remote Setpoint Select Option
• Dual Output/Dual Alarm Capabilities
• Optional Process Variable Retransmission
• cUL and CE Approvals
Downloads
Datasheet
Manual
Configuration Record Form
|
|
|
|
|
Series 18 and 19
|
|
The Athena Legacy 18 and 19 Controllers are available as 1/8 DIN (18) vertical or 1/8 DIN (19) horizontal models. Both panel mounted, auto-tuning controllers can be used for precise control of a single loop with two independent outputs. The controllers accept thermocouple, RTD, voltage, or current input. RS-232 or RS-485 communications are available, and two digital LED displays provide visual indication of various controller functions.
• Switch-Selectable Inputs
• User-Selectable Ramp to Setpoint
• Auto-Tuning, Heat or Cool
• Dual Output/Dual Alarm Capabilities
• On/Off Through Full PID Operation (P,PI,PD,PID)
• NEMA 4X (IP65) Dust and Splash-Proof Front Panel
• Bumpless Auto/Manual Transfer
• Adjustable Hysteresis & Heat/Cool Spread
• Field-Configurable Process, Deviation, or Latching Alarms
• Optional Process Variable Retransmission
• Remote Setpoint Select, Non-Linear Inputs, or Other Special Options
• cUL and CE Approvals
Downloads
Datasheet
Manual
Configuration Record Form
|
|
|
|